t f e w 11 frame transfor mount mers finish options voltage output style output power part numbering system example - l 030 f 15 i 030 = 30va 040 = 40va050 = 50va 080 = 80va 100 = 100va * available for certain sizes - please call for details. 06 = 2x6v* 09 = 2x9v*12 = 2x12v* 15 = 2x15v 18 = 2x18v 20 = 2x20v 24 = 2x24v t = thermal cutout* l = flying leads*i = vacuum impregnation e = additional enveloping*s = single 230v input f = frame example l030f15i = frame mounted 115v/230v input, 2x15v output, 30va transformer with vacuum impregnated varnish finish and solder tag termination. frame mount t ransformers *recommended fixing centres e 16 slots 'g' d b f a c 30 0.64 20 70 59 45 51 45 35 7 x 4 40 0.68 15 70 59 45 60 45 45 7 x 4 50 1 10 79 67 54 56 54 40 8 x 4 80 1.5 9 89 75 57 64 57 43 8 x 4 7 100 2.0 6 99 83 64 71 64 43 8 x 4 7 power mass regulation a b c* d e* f* g (va) (kg) (%) (mm) (mm) (mm) (mm) (mm) (mm) (mm) ? input voltages, single 230v or dual115v/230v 50/60hz ? reinforced insulation - tested at 3kvrms ? transformers dip coated in varnish asstandard ? solder tag terminations ? operational ambient temperature range-20 c to +50 c contact us now united kingdomcrydom +44 (0) 1202 897969+44 (0) 1202 891918 magnetics@crydom.com www.crydom.co.uk t f e w 10 c f e d a b *recommended fixing centres power mass regulation a b* c d e f (va) (kg) (%) (mm) (mm) (mm) (mm) (mm) (mm) 3 0.17 20 45 54 16 35 23 37 6 0.23 20 50 60 18 38 25 41 12 0.31 20 56 68 20 41 28 47 20 0.53 15 59 73 28 52 31 50 30 0.64 20 70 83 24 51 36 56 40 0.68 15 70 83 34 60 36 56 50 1 10 78 92 27 56 41 65 chassis t ransformers part numbering system example - l 003 c 15 i 003 = 3va 006 = 6va012 = 12va 020 = 20va 030 = 30va 040 = 40va 050 = 50va * available for certain sizes - please call for details. 06 = 2x6v 09 = 2x9v12 = 2x12v 15 = 2x15v 18 = 2x18v 20 = 2x20v 24 = 2x24v t = thermal cutout* l = flying leads*i = vacuum impregnation e = additional enveloping*s = single 230v input c = chassis example l003c15i = chassis mounted 115v/230v input, 2x15v output, 3va transformer with vacuum impregnated varnish finish and solder tag termination. ? input voltages, single 230v or dual115v/230v 50/60hz ? reinforced isolation - tested at 3kvrms ? transformers dip coated in varnish asstandard ? solder tag terminations ? operational ambient temperature range -20 c to +50 c finish options voltage output style output power cha transfor ssis mers usa crydom +1 619 210 1600 +1 619 710 8540 sales@crydom.com www.crydom.com
|